Premises Information

Return to Inspections
NameVUE, THE
Address215 N PINE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/18/2024
Final Score @ Grade
42
General CommentsNote: EHS who had visited the pool during the summer stated that the main drain screws seemed loose. Looked secure at time of inspection. Ensure secured. No suction on drains. Ashleigh Elliott present during the inspection. Pool closed signs posted during the inspection. Immediate Suspension issued for the emergency phone - .2530 - 911 and EHS shall be clearly audible. Phone shall connect to Charlotte 911 with correct address and phone number. Phone shall audibly ring or answer automatically when number is dialed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total alkalinity not recorded weekly. Record weekly. DPD- 1 and 2 expired. Replace expired reagents.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some staining in pool floor in deep end. Pool plaster shall reflect >50% light.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two of (7) skimmers missing weirs. Replace weirs in skimmers.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Damage to mesh at one gate. Repair. Horizontals are less than 45" apart. Damage to lower horizontal that ties into post at left gate. Repair fencing. Tennis court divider in front of the pool barrier. Store away from barrier to prevent a foothold.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed slip resistant coating on deck starting to degrade. Deck is concrete under coating. Monitor slip resistant coating, if degradation worsens a new coating may need to be applied. Deck holding water in some areas with discoloration from standing water. Does not appear slick at time of inspection. Eliminate standing water. Hole next to no diving marker located at handicap lift. Fill hole to eliminate opening in pool deck. Less than 1/2".
18 4 Premises: lifeguards present or warning signs posted No No No Pool signage and emergency phone blocked by cabana bed. Repeat non-compliance. Permanently move cabana bed so not to block signage.
22 6 Premises: emergency telephone provided No No No Phone connects to 911. Operator could not hear EHS. Phone shall be capable of connecting to 911. 911 shall audibly be able to hear EHS. Phone number and address could not be verified. Recording provided when connecting to 911 does not appear to be Charlotte emergency response. Verify that phone is connecting to Charlotte emergency response. Callback was not verified since phone not functional. Phone shall answer automatically or audibly ring when number is dialed. Immediate Suspension issued for both items.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Could not verify automated feeder. Head CPO not onsite at time of inspection. Feeder shall detect flow with loss of flow from pump. Be able to demonstrate.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Leak at left filter lid and also larger leak at return line valve. Repair leaks. No spare pump basket for pump. Pump basket in pump room not for pump installed. Provide spare pump basket.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at return line and filter lead. Keep pump room floor dry. Box of chemicals stored on chemical storage room floor. Store chemicals up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >114 F. Maintain at 110 F or below.