| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No chlorine in pool. Chlorine shall remain at least 1.0 ppm through NSF chlorinator. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No drain cover checks. Skimmers on side walls shall be verified daily to be secure and in good repair. Record in log book daily. ITS item.
DPD-2 reagent expired. Replace reagent. ITS item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae on pool walls and steps. Treat to keep pool walls clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with some debris. Basket at far end of pool with build-up. Keep skimmers free of debris. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Right step handrail loose. Tighten. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope on ring buoys tangled. Untangled during inspection. Keep accessible at all times.
Grab rope starting to degrade. Still intact. May require replacement prior to 2024 operating permit. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool umbrellas located next to pool so clearance not maintained. Pool cabana blocking pool rules sign. Pool chair blocking emergency phone. Move pool umbrellas to maintain clearance around pool. Move cabana permanently so signage is visible. Move chair so pool phone is visible. All are ITS items.
Deck surface starting to degrade. Monitor. May require repair in the future if worsens. Deck shall be maintained as slip-resistant. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Face of emergency phone not secure. Corrected during the inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket. Provide spare pump basket prior to 2024 operating permit. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water at >115 F in restrooms. Maintain at 110 F or below. |