| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed various weeks of daily written records lacking dates. Include dates for each day records are kept. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Staining on top steps into pool. Pool plaster does not meet LRV >50%. Plaster is dark.
.2514(c) Pool finish shall be white or light colored.
Build up observed on pool tiles around water line of pool wall.
.2514(c) Pool finish shall be white or light colored.
Some rust on drain covers. Does not appear to be sharp edge. Monitor and repair if worsens. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed two skimmer baskets in need of cleaning. Clean and maintain clean. Operator cleaned baskets while EHS present. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Observed loose handrail at pool steps. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed throw rope tangled and Beckett on one ring buoy in improper position. Ensure ropes are not tangled and Becketts remain in proper position. Operator corrected issue during inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gate on right side of pool to be not self closing. Repair gate to self close and self latch. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed standing water on deck and chipping damage on shallow section of deck. Ensure deck is kept free of standing water. If mildew becomes an issue with standing water, slope of deck repair will be required. Repair damaged deck area near shallow end of pool. Offsets not observed to be more than 1/2 inch and edges of chipped deck do not appear to present a hazard. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed Kings III emergency phone to be inoperable. Phone does not connect to 911. Phone must connect to 911 to verify correct phone number and address. Phone must audibly ring back when posted phone number is dialed. Immediate suspension issued. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed automatic feeder disconnected. Operator connected automatic feeder while EHS present. Ensure automatic feeder is operable at all times pool is open. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed water leaking from pump. Repair pump so that no water leaks. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed dry acid stored below liquid chemicals in chemical storage room. Store dry chemicals above liquid chemicals. Operator corrected storage order by placing dry acid above liquid chemicals. Observed standing water on pump room floor due to leak from pump. Repair to prevent standing water. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed springs in hot water handles to be broken in both restrooms. Fixtures shall be operable at all times pool is open. Repair or replace springs in hot water handles. |