| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
.2535(2) Main drains must be clearly visible from the pool deck. Observed pool water not clearly visible after pool Operator added sodium bicarbonate. Pool visibility was self corrected during inspection. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Maintain at 7.2 to 7.8. Immediate Suspension issued.
.2535(1) |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Some days missing from record keeping. Maintain chlorine, pH and main drain checks daily.
Some reagents expired. Replace reagents. New test kit was provided during inspection. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Staining on top steps into pool. Pool plaster does not meet LRV >50%. Plaster is dark.
.2514(c) Pool finish shall be white or light colored.
Build up observed on pool tiles around water line of pool wall.
.2514(c) Pool finish shall be white or light colored.
Some rust on drain covers. Does not appear to be sharp edge. Monitor and repair if worsens. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. Observed loose no diving tile on pool deck. Tile was secured during inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Observed loose handrail at pool steps. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope on ring buoy degrading. Replace with 45 ft rope. Immediate Suspension issued. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed broken horizontal next to gate 2. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to pool deck near shallow end. Offsets not greater than 1/2" and does not present cut/trip hazard. Continue to monitor and repair as needed.
Some pool furniture <6 ft. to pool edge. Maintain 6 ft. clearance around pool in all locations. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
.2524 For Night Swimming - provide sufficient lighting so that all parts of the pool and required deck area are visible and main drains are clearly visible. Pool is not approved for night swimming. If seeking night swimming, provide photograph documentation of operable perimeter and interior pool lights. Some lights burnt out. Adjust pool hours to reflect dawn to dusk. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Observed wrong phone number being transferred to 911. Number does not ring back to emergency phone. Immediate Suspension issued. |