Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVUE, THE
Address215 N PINE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/14/2021
Final Score @ Grade
34
General CommentsImmediate Suspension issued for drain covers. Once corrected, please contact Katie at 704-309-5494 to reopen the swimming pool. Pool is not approved for night swimming. If seeking night swimming, a site visit must be made to verify sufficient lighting in the pool and on the deck. Pool Closed signs posted during the inspection. Pool is to remain closed to the public until a return visit is made to re-open the swimming pool. Kristina Folks present during the inspection. Chlorinator verified on previous inspection. Will be verified for operating permit inspection in spring.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some days missing from record keeping. Maintain chlorine, pH and main drain checks daily. No record for yearly inspections on Paddock covers. Provide inspection record. DPD-2 reagent expired. Replace reagent.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No One screw loose/drain cover popping up on drain cover closest to street side and emergency phone. Does not appear that drain screws are all installed. Install drain cover screws per mfg. instructions. Immediate Suspension issued. .2537(7) Drain covers shall be in good condition and securely attached.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Two skimmers with bicarb stuck in lines. Repair skimmers so fully operable.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed <45" between bottom horizontal and next horizontal on perimeter fencing. Pool built 4/30/2010. Maintain 45" between horizontals.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool umbrellas <6 ft to pool edge. Maintain 6 ft. clearance around pool in all locations. Some damage to coating on deck at shallow end. Keep decking in good repair.
18 4 Premises: lifeguards present or warning signs posted No No No (1) Warning sign with lettering faded. Replace with 4" lettering. "Warning - No Lifeguard on Duty". Pool rules signage blocked by large lounge chair. Move chair so that pool rules signage is visible upon entry to the swimming pool.
22 6 Premises: emergency telephone provided No No No Phone number not posted at emergency phone. Written in with sharpie during the inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in men's restroom. Women's soap dispenser not operable. Provide soap in restrooms.