Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed no record keeping for main drain checks. Observed alkalinity and cyanuric acid not recorded weekly. Record daily main drain checks and weekly cyanuric and alkalinity readings.
Maintenance supervisor no longer with the property. Provide updated CPO information.
Intent to Suspends issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed damage to some skimmer lids. Continue to monitor and replace if worsens to present hazard to public.
Observed one weir missing from skimmer. Replace weir. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed some corrosion on cuplings at bottom of step handrails. Keep in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed <45" between bottom horizontal and next horizontal on perimeter fencing. Pool built 4/30/2010. Maintain 45" between horizontals. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture 5 ft. to pool edge. Maintain at least 6 ft. clearance around the swimming pool at all times.
Some deck damage where finish has begun to chip. Continue to monitor so as not to become a hazard to the public. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Keep operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light in chemical storage room burnt out. Replace light.
Pump room left unlocked. Keep locked when not in use. |