3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Chemicals added with no change. Maintain at 7.2 to 7.8. Immediate Suspension issued.
.2535(1) Maintain pH at 7.2 to 7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Main drain checks not recorded daily. Alkalinity and acid not recorded weekly.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer missing weir. Two skimmers near tennis court and lift with no pull.
.2518(k) Surface skimmers shall be installed per manufacturer's instructions.
.2518(k) Replace missing weirs.
Water level high on skimmers so not operating per manufacturer specifications.
.2518(k) Water level shall be maintained to assure skimmers are operable. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy ropes tangled and not easily accessible. Corrected during inspection.
.2530(a) Lifesaving equipment should be conveniently located. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Damaged plexiglass on one gate which allows for less than 45" between horizontals. Repair plexiglass to maintain 45' or greater between horizontals.
.2528(b) Horizontals shall not be located less than 45" in height.
<45" between horizontals on fence. Pool fence installed pre-2010. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Corrected during inspection.
.2518(g) Keep flow meter operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Bag of bicarb stored on pump room floor. Maintain chemical storage up off the floor.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib for pump room without backflow prevention. Located in dog park area. Provide backflow prevention device.
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Note: If required to replace check valve for fill line, ensure meets code of .2512. |