Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOMFORT SUITES
Address14510 BOULDER PARK DR NORTH
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/11/2025
Final Score @ Grade
32
General CommentsInspection conducted with CPO Ajay Patel. Underwater lights not functioning. Many of the wall and ceiling lights not functioning in the pool area. Ensure lighting is maintained and pool area is well lit. Pool heater was off at the time of inspection. Ensure that water temperature is maintained at no more than 90F when heater is on. Immediate suspension issued 2) 15) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for total alkalinity and cyanuric acid if used. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. Pool floor and walls with chipping and etching. .2537(14) Maintain pool floor and walls in good condition. Heavy buildup on pool wall tiles. .2537(14) Maintain pool floor and walls in good condition.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail loose. .2521 Install handrails per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope for ring buoy missing. .2530(a) Provide USCG approved ring buoy with attached 15 foot throw rope at least 1/4” in diameter. - Immediate suspension item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No longer using EcoLab chlorinator, now using salt system pool was built with. Salt system not working properly. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Buckets of chemicals stored next to pool piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Not able to access chemical storage room to inspect. Buckets of chemicals stored directly outside the chemicals storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.