Water quality: pool water pH |
No |
No
|
No |
PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkalinity records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity. - Pre-permit item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Pre-Permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail loose. .2521 Install handrails per manufacturer instructions.
Ladder loose. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy damaged. Throw rope only 12 feet long. .2530(a) Provide USCG approved ring buoy with attached 15 foot throw rope at least 1/4” in diameter. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both doors not self-closing and self-latching. .2528(a) Ground level doors shall be self-closing, and self-latching. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Buckets of chemicals stored next to pool piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Not able to access chemical storage room to inspect. Buckets of chemicals stored directly outside the chemicals storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |