NameCOMFORT SUITES
Address14510 BOULDER PARK DR NORTH
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/16/2023
Final Score @ Grade
22
General CommentsConducted pre-permit inspection with CPO Michael Henson. David Johnson is the new CPO for this pool. Updated CDP with CPO information. Pre-permit items from previous inspection have been corrected. Emergency phone calls back to the front desk. Ensure front desk is staffed whenever the pool is open. EcoLab automatic feeder reading 4.58 for pH. Tested today at 8.4. Recommend recalibrating the controller. Door to pump room, chemical storage room, and heater with sticky latch. Doesn’t always latch when closed. Ensure door stays closed, locked, and inaccessible to the public when not in use. Permit issued Paper permit will be available on our website https://health.mecknc.gov/envhealth/pools in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty records. Pool checked 4 days in last 2 weeks. No total alkalinity checks or maintenance activities. No place for temperature checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for total alkalinity. - Corrected. Operator now using state sheet. Tested chemicals today.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One of two weirs missing. .2518(k) Replace missing weir. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrail loose. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to stairwell not self-latching. .2528(a) Ground level doors shall be self-closing, and self-latching. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No light in the chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.