Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOMFORT SUITES
Address14510 BOULDER PARK DR NORTH
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/13/2019
Final Score @ Grade
40
General CommentsOperator had been hand feeding chlorine. Some residual chlorine tablets in one of the skimmer baskets. Removed by operator. Posted permits are expired. Posted new sticker. Go to Meckpools.Charmeck.org to print the current pool permit and post in the pool area. Immediate Suspension Issued: 2) 3) 22)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Cl 0ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate Suspension Item.
3 6 Water quality: pool water pH No No No pH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate Suspension Item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records since June. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to Suspend Item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Pool floor dirty. .2537(14) Keep pool surface and pool floor free of debris. - Intent to Suspend Item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weirs. - Intent to Suspend Item. One skimmer float valve assembly clogged. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected by operator.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 12 feet long. .2530(a) Provide ring buoy for 15 foot throw rope. Corrected by operator.
22 6 Premises: emergency telephone provided No No No Emergency phone not easily accessible, very difficult to open the phone box. .2530(f) Emergency phone shall be accessible to all pool users. Corrected by operator. Emergency phone not operating. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate Suspension Item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator not functioning. Operator had been hand feeding chemicals since it failed. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.