NameCOMFORT SUITES
Address14510 BOULDER PARK DR NORTH
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/19/2019
Final Score @ Grade
28
General CommentsHandrail loose. Maintain secure and in good condition. Pool has a dedicated vacuum line. Recommend using dedicated vacuum line to vacuum the swimming pool. If skimmers are used ensure that skimmer baskets remain in place and skimmer adapter used to vacuum through the skimmer. Immediate suspension issued. 2) 3) Contact Will Harrison (704-507-6824) for reinspection when immediate suspension items have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.4 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
3 6 Water quality: pool water pH No No No pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Total alkalinity readings look like temperature readings and vice versa. Looks like operator takes readings from control board. Use test kit to determine water chemistry. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Drain cover for hydrostatic relief valve loose. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to pool area not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum fitting installed on far skimmer return line. .2518(f) Skimmer vacuums may only be used for pools with two or fewer skimmers provided that skimmer baskets remain in place. Remove vacuum fitting from skimmer return line. - Intent to suspend item.