NameCOMFORT SUITES
Address14510 BOULDER PARK DR NORTH
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/23/2018
Final Score @ Grade
22
General CommentsHandrail loose. Maintain secure and in good condition. Pump was at speed 2. Permit condition is for pump to be locked at speed 3. Corrected to speed 3, will need to be password locked to this speed. Intent to suspend issued. Pump locked at speed 3 8) 12) 17) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 Records are the same every day. Total Alkalinity reading looks like the temperature reading and vice versa. Check daily with a pool test kit Cl, pH, and check main drains, temperature and pool maintenance activites. Check at least weekly Total Alkalinity and Cyanuric Acid if used.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Missing one of two weirs. Replace missing weirs. - Intent to suspend item. .2518(k) Very little flow through the skimmers. The flow-through rate through any one skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Cover for hydrostatic relief valve has been removed. Fittings and/or face plates shall be replaced when damaged and kept in good repair.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Hole in the deck where anchor for spa handrail was. Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Flow meter stuck. Keep flow meter operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2533(d) Water regularly comes out of the overflow in the chlorinator and spills onto the floor. Pump room floor shall be kept dry and free of standing water. .2534(6) Provide sufficient lighting in chemical storage room. .2534 Chemicals stored in pump room. Store all chemicals in chemical storage room.