NameHILTON GARDEN INN
Address425 TOWNE CENTRE BLVD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/17/2024
Final Score @ Grade
14
General CommentsOBSERVED THE PUMP MOTOR TO BE SWAPPED. MOTOR IS STILL A 1.5HP MOTOR AND HAS THE GROUND WIRE CONNECTED. AN ELECTRICAL INSPECTION FOR THIS WAS NOT PERFORMED. THIS WORK REQUIRES AN ELECTRICAL INSPECTION/PERMITTING FROM CHARLOTTE-MECKLENBURG CODE ENFORCEMENT FOR ELECTRICAL WORK. IT IS STRONGLY RECOMMENDED THAT THE POOL BE CLOSED UNTIL THE ELECTRICAL INSPECTION IS PERFORMED AND IS PASSED. OPERATION OF THE PUMP AND MOTOR WITHOUT PASSING ELECTRICAL INSPECTION IS AT THE RISK OF THE FACILITY AND STAFF. POOL MAIN DRAIN COVERS AND EQUALIZER LINE COVERS WILL EXPIRE IN APRIL 2025. THEY MUST BE REPLACED WITH PROPER COVERS THAT WILL HANDLED THE FLOW RATE OF THE SYSTEM AND THE PDSC PAPERWORK SUBMITTED AND APPROVED BY THE HEALTH DEPARTMENT PRIOR TO THE EXPIRATION OF THE COVERS. BE AWARE THAT THERE IS A NEW FLOW RATING STANDARD AS OF 2017 AND THAT FLOW RATES FOR COVER MODELS MAY HAVE CHANGED. DOUBLE CHECK ANY NEW COVERS TO MAKE SURE THEY WILL PROPERLY HANDLE THE FLOW RATE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed the outdoor pool floor to be damaged. This will only get worse over time and will eventually prevent the pool from being permitted to operate. No permit action taken at this time.
13 4 Pool maintenance: contrasting band on steps and benches No No No .2521(b) Provide at least 2" contrasting color band to edge of stair treads. .2516(b) Underwater benches shall be marked by a two inch contrasting color band. .2521(b) Contrasting color band shall be clearly visible. Observed the outdoor contrasting bands to be fading. This will only get worse over time and will eventually prevent the pool from being permitted to operate. No permit action taken at this time.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed ring buoy to be damaged beyond reasonable use. A new buoy was obtained. It is a hard plastic model that does appear to meet the Coast Guard certification. Corrected during inspection.