15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
New buoy rope on inside buoy too long at time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Manager cut and corrected to 27'.
Body hook outside inaccessible due to table and chairs. Keep accessible.
.2530(a) Lifesaving equipment should be conveniently located. Manager moved furniture to make accessible. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door on left from conference room onto pool deck not self-latching or alarmed at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool table, chairs, furniture with 5' of pool inside and within 6' of pool outside.
.2522(b) Provide at least 5 ft of clear walking space around the pool inside at all times.
.2522(a) Provide 6 ft of clear walking space around the pool outside at all times.
Manager moved furniture and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No ventilation in chemical storage or pump room at time of inspection. No cross vent observed, only vent at top of rooms. Some bags of chemicals stored on floor in chemical storage. Pool built '01. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |