Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON GARDEN INN
Address425 TOWNE CENTRE BLVD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/8/2018
Final Score @ Grade
16
General CommentsITS for records, depth markers (on deck) and CPO.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly TA and CA and pool water maintenance. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Provide documention of CPO. 30 Day Intent to Suspend (ITS) item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 4 Ft marker on pool walls, but not on deck. .2523(a) Provide depth markers on pool walls and pool deck at points of maximum and minimum depths. **30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs outside within 6' of pool. Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Standing water in pump room. Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom over 110 degrees F. Water in restrooms shall not exceed 110 F.