6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Skimmer equalizer drain cover Waterway 640-803xv installed 2/2011, has expired at time of inspection (2/27/2018) with 7 year lifespan.
Issued Immediate Suspension. 'Pool Closed' signs posted at bather entrances. May not be removed or open until Suspension is lifted. Provided PDSC Form information and instructed operator to complete. Must be approved (may submit to Katie Wilson) and contact Marie Daley at 704-507-6806 when approved form has been submitted and new drain cover is installed according to manufacturer's instruction to lift Immediate Suspension |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves and debris. Keep clean. Operator cleaned. Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Extra ring buoy on deck with rope 25'. Rope must be width and half of pool (27'). Buoy removed from deck. One ring buoy in compliance left in pool enclosure. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and tables within 6' of pool. Maintain 6' deck clearance (outside). 5' clearance indoors. Operator moved. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working properly at time of inspection. Ensure flow meter is working properly.
***Intent to Suspend item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Standing water in the pump room. Pump leaking. Keep area dry. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Hot water exceeding 130 degrees F in restroom. Maintain hot water at 110 degrees F and below. |