| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
pH 7.0 and free chlorine 0.1 at time of inspection. Maintain pH 7.2 to 7.8 and free chlorine at least 1.0 ppm. Operator corrected to 7.2 and 1.0 ppm. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Cyanuric Acid and Total Alkality missing on records. Record weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor starting to peel. Keep in good repair.
**Operator stated that bids are in to redo pool floor. Contact Katie Wilson at 704-309-5494 for in-field plan review questions or main office at 980-314-1620 for application when renovation or repairs are done to the pool. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and tables within 5' of pool. Maintain 5' deck clearance. Operator moved. Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency telephone reads "Dial 911" at time of inspection, but automatically dials 911 when receiver is lifted. Dialing instructions must be correct for emergency phone. Operator made new, correct dialing instructions. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working properly at time of inspection. Ensure flow meter is working properly. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Standing water in the pump room. Pump leaking. Keep area dry.
Chemicals stored in pump room. Store separately. Operator moved chemicals. Corrected. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Pipes not clearly identified. Exposed pipes and vavles shall be identified by a color code or labels. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water reaching 140 degrees F in restroom. Maintain hot water at 110 degrees F and below. |
|