Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANA AVEBURY APARTMENTS
Address2410 ALLERTON WAY
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/28/2026
Final Score @ Grade
6
General CommentsPermit Restriction: Flow meter must remain operable. Flow required at 106 gpm or pump speed required at 3450 RPM. Turnover not met due to flow restriction of the filter. Pump was adjusted to maintain 93 GPM with flow meter to meet flow on PDSC form. POOL IS NOT APPROVED FOR NIGHT SWIMMING. C. ELMORE VERIFIED THE FOLLOWING ITEMS New Pump Pentair Intelliflo3 VSF, 3 hp pump (011076) Aquastar Flow Meter PM30 on 3” pipe with at least 15” straight run pipe before the flow meter and 6” after the flow meter. 3” main drain, skimmer and return line Lawson MLD-SG-0909 2017 drain covers Pentair TR140 filter 14 returns, either on the wall or floor (6) skimmers AS WELL AS PDSC FORM AND THE ELECTRICAL INSPECTION. POOL HAS PASSED INSPECTION AND BEEN ISSUED PERMIT DECAL. POST PERMIT DECAL AND PAPER POOL PERMIT DOCUMENT AT THE POOL. THE PAPER PERMIT SHOULD BE AVAILABLE WITHIN 1-3 BUSINESS DAYS ON THE HEALTH DEPARTMENT POOL WEBSITE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence is not to current specifications. Pool built prior to 2010. No permit action taken.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line not discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.