Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANA AVEBURY APARTMENTS
Address2410 ALLERTON WAY
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/6/2022
Final Score @ Grade
12
General CommentsPOOL IS NOT PERMITTED FOR NIGHT SWIMMING. POOL MAY ONLY BE OPEN SUNRISE TO SUNSET. IF YOU WISH TO HAVE THE POOL EVALUATED FOR NIGHT SWIMMING, PLEASE CONTACT C. ELMORE AT 704-507-6814. OBSERVED POOL FILTER TO BE NEW. CURRENT FILTER IS RATED FOR 106 GPM. MAXIMUM FLOW FOR THE PUMP IS 160GPM. FLOW AT 65 FOOT OF HEAD WAS LISTED AT 135 GPM, FLOW RATE AS MEASURED BY FLOW METER AFTER BACKWASH WAS 105 GPM. CHANGE WAS DONE WITHOUT PLAN REVIEW SUBMITTED. CHANGE WAS REVIEWED IN THE FIELD. PERMIT RESTRICTION WAS ADDED THAT THE FLOW RATE OF THE FILTER, 106 GPM, CANNOT BE EXCEEDED BY THE SYSTEM AND THAT THE FLOW METER MUST WORK PROPERLY TO MEASURE THE FLOW. CURRENT FLOW RATE OF 105 GPM AS MEASURED IS ACCEPTABLE. “FLOW THROUGH THE SYSTEM CANNOT BE MORE THAN 106 GPM WITH THE CURRENT FILTER (PENTAIR TRITON II, TR-140 AS OF 7/6/2022). THE FLOW METER MUST ALSO WORK PROPERLY TO MEASURE THE FLOW. (C. ELMORE #2338, 7/6/2022)“ WAS ADDED TO THE PERMIT AS A PERMIT CONDITION. EQUALIZER LINE COVERS AND MAIN DRAIN COVERS WILL EXPIRE IN FEBRUARY 2023. THEY MUST BE REPLACED AND THE PDSC PAPERWORK FOR THE REPLACEMENTS SENT TO THE HEALTH DEPARTMENT AND APPROVED PRIOR TO EXPIRATION. ENSURE REPLACEMENT WITH PROPER COVERS FOR THE FLOW RATE. POOL HAS PASSED INSPECTION AND BEEN ISSUED THE PERMIT DECAL. PAPER PERMIT WILL BE AVAILABLE ON-LINE AT THE HEALTH DEPARTMENT WEBSITE. DISPLAY THE PERMIT AND DECAL AT THE POOL DECK AREA.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy throw rope to be 42 feet long. 30 foot long rope is required. Rope was cut to proper length. -C.D.I.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed some damage to the fence. Keep fence in good repair. Barrier built prior to 2010. No Permit Action taken.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line.