Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANA AVEBURY APARTMENTS
Address2410 ALLERTON WAY
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/3/2019
Final Score @ Grade
24
General CommentsContrasting color bands on steps fading. Recommend repainting. Recommend recalibrating the automatic feeder. Immediate suspension issued. 3) Contact Will Harrison (704-507-6824) for reinspection when issues corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records for just a few days last month. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. One skimmer with very little flow, two other skimmers with no flow. .2518(k) The flow-through rate through any one recessed automatic surface skimmer shall be between 20 gallons per minute and the maximum flow the skimmer is certified for under NSF Standard Number 50. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. .2530(a) Provide US Coast Guard approved ring buoy with 30 foot throw rope. - Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in the chemical storge room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Chemicals stored in the pump room, chemical storage room partially used for general storage. Store all pool chemicals in the chemical storage room, remove unrelated items from the chemical storage room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Post a shower sign visible upon entrance to the pool.