Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVANA AVEBURY APARTMENTS
Address2410 ALLERTON WAY
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/6/2019
Final Score @ Grade
54
General CommentsBody hook with one, heavily rusted screw. Recommend securely attaching body hook to pole with two screws. Chemical line resting on pool pump. Recommend running lines from liquid acid and chlorine along the walls. Recommend installing chemical safety sign on chemical storage room door. Operator not present. Unable to test that automatic chlorinator stops feeding when the pump shuts off. One gate locked. Ensure that gates meet all requirements. Immediate suspension issued. 2) 3) 15) 22) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
3 6 Water quality: pool water pH No No No pH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records kept since mid January. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain cyanuric acid at no more than 100 ppm. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Floating debris and leaves in the pool. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers full of leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. Skimmer basket with a hole in the bottom. .2518(k) Replace missing or damaged skimmer basket. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. Becket loose. .2530(a) Provide USCG approved ring buoy with 30 foot throw rope. - Immediate suspension item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chairs and tree too close to the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
18 4 Premises: lifeguards present or warning signs posted No No No Deck chairs placed directly in front of some of the emergency signage. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No 911 does not have a phone number for the emergency phone. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap missing. Vacuum off in the pump room. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Intent to suspend item. Flow meter stuck. Labeling worn and difficult to read. Flow meter installed on an elbow. .2518(g) Install and maintain operational flow meter capable of measuring 1.5 times the design flow rate on return line per manufactuer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. Store all chemicals in the chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper dispenser ripped off of the wall in the men's restroom. .2626(l) Provide toilet paper and dispensers in restrooms.