Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND SOUTH END - COURTYARD A
Address2225 HAWKINS ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/2/2017
Final Score @ Grade
20
General Comments#33 CPO & EHS unable to locate hose bib within 50' of restroom (for use w/ restroom floor cleaning, etc.) See .2526(d). Note: EHS observed ground level windows that are present on pool & spa deck/ courtyard enclosure. Ground level windows shall be protected by audible alarms or may not open greater than 4" on to pool deck. ***EHS recommends that the apt complex management contact their phone carrier & request that a notation be added to the emergency phone number which would allow the 911 operator that the call is originating specifically from Courtyard A pool & spa (@ 2225 Hawkins Street). INTENT TO SUSPEND issued for #8. (weir in disrepair)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed scum/ soil on pool wall tiles. ** Clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir disrepair/ missing Styrofoam preventing weir from functioning properly. ** Replace this weir.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed deck furniture as close as 2' from pool edge. ** Maintain 6' of clear walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter float stuck. ** Keep flow meter operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No -- Forced air ventilation in equipment room is inoperable. ** Repair/ replace if necessary. -- Observed liquid chlorine & liquid acid in equipment room. ** All pool chemicals should be stored in chemical room; however, chemical room location not close to equipment room. -- Chemical room has light fixture; however, it is not of a pull chain design nor could a light switch be found. ** Provide lighting in chemical room as required.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water at least 134F @ lavatories in restrooms. ** Maximum hot temperature allowed is 110F. Pink bacterial growth on under top rims of urinals. ** Clean.