Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameJEWISH COMMUNITY CENTER - INDOOR/OUTDOOR STAR POOL
Address5007 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/30/2024
Final Score @ Grade
28
General Comments11 - Not all dive platforms installed. Dive platforms uniform in construction. Ensure all dive platforms no greater than 30" from waterline to platform. 15 - Grab rope on ring buoy damaged. Pool sometimes only has one lifeguard. Provide new USCG approved ring buoy within 1 week. Photograph will suffice of new buoy. Rope ok at 50 ft. New ring buoy provided. Picture provided. Phase 1A - Scope includes additional of back wooden fence and enclosure of tent storage area.B4592231. New flooring overlay in restrooms. Mirrors existing. Phase 1B - Scope includes the completion of the back patio area outside of pool deck. Unisex RR. Needs inspection prior to release of hold. B4610459. Phase 2 - Scope includes installation of the new tent over the pool. B4610476. Phase 1A Construction passed. Hold will be released in system. TCO on building/plumbing/mechanical and final on electrical. Fire permit moved to phase 1B. Spoke with Code Enforcement. No finals will be given on project until all work is complete. Josh Steinberger present during the inspection. Provided documentation that screws changed on drains on 5/15/2024. Drains inspected during install.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No New barrier installed around pool including wooden fence. Gate that leads into pool from main walkway with horizontals less than 45" apart and >2" from ground to bottom of gate. Requires repair prior to finaling. Photograph documentation provided of repair. Fence around heater not secured. Corrected during the inspection. Railings that lead up to pool gates provide horizontals at 45" or less. Required by Code Enforcement for step entry. Maintenance gates that swing into pool. Gates are kept locked when not in use. Original barrier installed in 2003.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Two areas of deck with damage. Require patch prior to hold release. Pictures provided.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lights not operable. Permit will be issued for no night swimming and shall be verified prior to approval for night swimming.
22 6 Premises: emergency telephone provided No No No Emergency phone not visible from pool deck. Additional signage provided on deck for location of emergency phone. Permanent signage will be provided.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational. No flow restriction on system. Keep flow meter operational. Flow meter on 6" line. Requires at least 24" of straight run pipe. Installed with 22". If replaced, install per mfg. instructions.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Drain pipe for sink across floor. Provide 3 ft. clearance to eliminate trip hazard in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at drain line to pit. Provide air gap or backflow prevention.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >112 F. Maintain at 110 F or below. One stall missing toilet paper. Provide toilet paper in restrooms.