9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed 2 depth markers around pool with peeling lettering. CDI- repaired using permanent marker. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed no body hook inside pool enclosure. CDI- body hook provided. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed holes in pool deck for ladders or poles not properly covered or capped. CDI- holes were capped to prevent trip hazard. |