Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameJEWISH COMMUNITY CENTER - INDOOR/OUTDOOR STAR POOL
Address5007 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/28/2017
Final Score @ Grade
28
General CommentsObserved the body hook to be attached to the pole with plastic pinch type attachment hardware. Connect all body hooks to poles with screws and nuts as needed. Do not continue to use the plastic attachements only.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed temperature check not being recorded with daily log. Temperature must be recorded daily.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed pool floor etched.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Observed depth marker peeling off side wall. Observed "FT" tile to need replacing on the deck. Correct such that all depth markers on the side walls and the deck are properly posted.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy throw rope to be 58ft. long. Rope was corrected to 50ft. -C.D.I."
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed electrical grounding wire to have become exposed in the grooves on the deck. Cover all of the wire with grout or other permanent coating. Observed various holes on the deck to accomodate the posts that hold equipment. Provide plugs for these holes such that the difference between the top of the plug and the deck is a 1/2" or less offset.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter to be stuck. Repair flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed acids and bases stored together in chemical storage. Separate them in storage. Observed sink drain in pump room to be a trip hazard. Eliminate trip hazard.