Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/10/2026
Final Score @ Grade
24
General CommentsGerald Astacio present during the inspection. 19 - Note - Pool rules signage indicates no animals. If ever replaced, replace with no pets wording. Permit Restriction: 1) Flow meter must remain operable. Flow shall not exceed 420 gpm due to filter flow restriction. Note - Permit applications are due by end of business on February 27th or late fee will be charged.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope note attached. Corrected during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 5 ft. to pool edge. Maintain 5 ft. clearance around the pool in all locations.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on bromine stick feeder. Required for NSF approval. If repaired/replaced, install with flow meter per mfg. instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Multiport leaking on filter closest to back wall. Repair leak at multiport. Leak was not large and did not warrant permit action at the time of the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Dry chemical stored in box on the chemical storage room floor. Moved during the inspection. Maintain dry chemicals, not in waterproof containers, up off the floor. Water under leaking multiport in pump room due to leak. Keep floor dry.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor does not appear slip-resistant in restrooms. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original construction. Floor shall be sloped to drain with drain and hose bib present.