Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2025
Final Score @ Grade
22
General CommentsIntent to Suspend issued for .2535(10) - Need new test kit reagents. Current ones expired. Gerald present during the inspection. Main drain covers expire in 2028. A like for like replacement will not be approved. Kurtis Nelson conducted inspection with Katie Rudisill.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Few days missing from log book. Ensure daily record keeping for main drains, Bromine and pH. Ensure weekly record keeping for total alkalinity. Days not inconsistent enough to warrant permit action. Permit action will be taken in future if issue persists. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Testing reagents expired. ITS issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 5 ft. to pool edge. Maintain 5 ft. clearance around the pool in all locations.
22 6 Premises: emergency telephone provided No No No 2530. Emergency phone could not receive calls. Was repaired during inspection with new phone. Will verify the call back, dialing instructions, address, and phone number on new permanent phone when returning for the ITS verification.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on bromine stick feeder. Required for NSF approval. If repaired/replaced, install with flow meter per mfg. instructions.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor does not appear slip-resistant in restrooms. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original construction. Floor shall be sloped to drain with drain and hose bib present.