Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/13/2025
Final Score @ Grade
30
General Comments1 - Pool slightly cloudy. Main drains and pool floor visible. If worsens, close pool to public to allow water to clear prior to reopening. Brandon Flannery present during the inspection. Intent to Suspend issued for: .2518 - install flow meter per mfg. instructions without angle.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 8.4. Lowered to 7.2 during the inspection. Maintain at 7.2 to 7.8.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalinity not recorded weekly for last two weeks in December/beginning of January. Ensure weekly record keeping for total alkalinity.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on pool floor near ladder (closest to emergency phone). Ensure pool floor kept clean.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture less than 5 ft. to pool edge. Maintain 5 ft. clearance around the pool in all locations.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on bromine stick feeder. Required for NSF approval. If repaired/replaced, install with flow meter per mfg. instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter does not appear to be installed per mfg. instructions. Flow meter required for permit restriction on filters. Install flow meter per mfg. instructions/not at angle. Intent to Suspend issued.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor does not appear slip-resistant in restrooms. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original construction. Floor shall be sloped to drain with drain and hose bib present.