Inspection Date 12/7/2022
Final Score @ Grade
30
General CommentsIntent to Suspend issued for the following: .2535 - maintain daily record keeping for main drains and weekly record keeping for total alkalinity .2528 - repair door to self-close, self-latch .2518 - repair leak at filter and ensure operable pressure gauge (3rd filter from door) .2518 - repair flow meter. Flow restriction on pump. Flow meter must remain operable with flow not to exceed 420 gpm limit of filters. Note: HVAC/dehumidifier not operational at time of inspection. Pool deck was very humid. Ensure monitoring for mold and cleaning as needed until system is repaired. Brian Vinger present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain checks not recorded daily and total alkalinity not recorded weekly. Maintain daily record keeping for main drain checks and weekly records for total alkalinity. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on pool floor. Keep pool floor clean. Caution: Sand in pool usually indicates a broken lateral in the filter.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main door on to pool deck not latching. Repair door to self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Large chair and some footstools blocking pool deck. Maintain 5 ft. clearance around the swimming pool.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on bromine stick feeder. Required for NSF approval. If repaired/replaced, install with flow meter per mfg. instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter reading 0 gpm. Flow restriction on system due to filters. Repair so operable. Flow meter must not read >420 gpm. Intent to Suspend issued. One of three filters not operable due to leak. Pressure gauge not operating. Repair leak/filter and ensure pressure gauge is operable. Intent to Suspend issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink in men's not operable. Keep all fixtures in good repair.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor does not appear slip-resistant in restrooms. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original construction. Floor shall be sloped to drain with drain and hose bib present.