Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/16/2022
Final Score @ Grade
28
General CommentsIntent to Suspend issued for alkalinity reagents, test kit replacement, and depth marker. Ring buoy grab rope starting to degrade. Given 30 days to provide new USCG approved ring buoy. If replacing rope, must be required 25 ft. Will verify on return visit for ITS items. Gerald Astacio present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Reagents for total alkalinity expired. Replace reagents - R008 and R007. Replace testing tube kit. Black build-up in test kit. Intent to Suspend issued for reagents and new kit.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on pool floor. Keep pool floor clean. Caution: Sand in pool usually indicates a broken lateral in the filter.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker peeling off wall at 4 ft. depth marker located on exterior of glass. Repair depth marker to ensure 4" lettering height. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Large chair and some footstools blocking pool deck. Maintain 5 ft. clearance around the swimming pool. Furniture moved during the inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on bromine stick feeder. Required for NSF approval. If repaired/replaced, install with flow meter per mfg. instructions.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet near UV system/last filter. Monitor for leaks. Did not see any while onsite. Pump room floor shall be kept dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink in women's restroom not operable. Repair so operable.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor does not appear slip-resistant in restrooms. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original construction. Floor shall be sloped to drain with drain and hose bib present.