NameRITZ-CARLTON CHARLOTTE, THE
Address201 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/27/2019
Final Score @ Grade
22
General Comments22 - Emergency phone signage faded and peeled. Still legible. Replace with new sign with dialing instructions and correct address and phone number. Replace within 30 days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool pH at 6.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Test kit provided with incorrect reagents for testing pH. Provide test kit that can accurately measure pH. Intent to Suspend item. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Alkalinty not recorded weekly. Consistent measurements taken until the last week and a half. Record alkalinity weekly.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Repeat Non-Compliance: Pool furniture less than 5 ft. to pool edge in several locations. Move furniture to ensure clear walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Digital flow meter in place and reading 0 ppm. Flow meter shall read accurate flow rating.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Wet chemicals stored over dry chemicals in chemical storage room. Corrected during inspection.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No .2626(c) Floor drains shall be provided in restrooms. .2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. No hose bib or floor drains in restrooms. Restrooms were constructed without.