5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No alkalinity checks in logs and dates not recorded for logs.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Drain cover missing screw and not secure. When operator tried to install new screw, appeared that covers are not installed per manufacturer specifications. No way to secure to secure screw. Immediate Suspension issued.
.2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7.
.2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used.
.2537(7) Drain covers shall be in good condition and securely attached. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Pool wall depth markers located inside of pool and not visible on pool walls. Provide perimeter wall depth markers so that depth is clearly visible.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder loose.
.2521 Install ladders per manufacturer instructions. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Repeat Non-Compliance - Deck furniture less than 5 ft to pool. Maintain 5 ft clearance around pool at all times. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Repeat Non-Compliance - Pump leaking. Previous inspection indicates in March that gasket was ordered. No repair made. Repair pump.
.2518(h) Provide approved pump in good repair.
Repeat Non-Compliance - Flow meter not reading.
.2518(g) Keep flow meter operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light burnt out in chemical storage room.
.2534(6) Provide sufficient lighting in chemical storage room.
Pump room floor wet at leaking check valve and around pool pump.
.2533(d) Pump room floor shall be kept dry and free of standing water. |