Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCORTLAND COTSWOLD
Address4817 WATER OAK RD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/12/2026
Final Score @ Grade
24
General Comments30 Day Intent to Suspend (ITS) issued for records, decking, gates and flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. “W” ITS status Pool not heated. No night swimming. Inspection with Crystal Petty

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly readings total alkalinity and cyanuric acid and out of range pH with no maintenance/chemicals actions taken to correct. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers full of debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose, coming out of decking. .2521(b) Ladders shall be installed rigidly.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate latch not working at all, gate in back not latching at close and swinging inward. Unsure if this has been changed or due to topography. Will verify at return visit. Fence was built prior to 2010. Not built to current specifications. No permit action taken. .2528(b) Gates may only swing toward pool if built prior to May 1, 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. .2528(a) Gate latches shall be 54" in height. .2537(b) All gates and doors shall be self-closing, self-latching. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Decking pavers around ladder not secure to pool deck, coming out and offsets greater than 1/2”. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(2) Decks shall be kept in good repair. *Permit item Chairs within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Manager moved and corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck at top, no legible numbers for reading. .2518(g) A flow meter, reading in gallons per minute shall be installed per manufacturer instructions. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals in pump room. No 3’ clearance. Different chemicals stored on top of liquid vats. Pool built 1986. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.