3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 6.8 upon arrival. Corrected to 7.4 |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (4) Lower and maintain cyanuric acid at or below 100 ppm.
Observed two days missing in the log record for this month. Corrected by education. No Permit Action taken. Keep proper records. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence was built prior to 2010. Not built to current specifications. No permit action taken. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed deck furniture to be too close to the water. CDI Items were moved back. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bags of pool chemicals on the floor. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no air gap at the backwash line. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(i) Water in restrooms shall not exceed 110 F. Water in restrooms temperature reached 129F. Turn down temperature to reach compliance. |