16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gates not to be self-closing and self-latching. Observed gates to have openings greater than 4" through the gates. C. Elmore directed the gates be locked until they are corrected to be self-closing /self-latching to prevent access by children. Observed gaps greater than 2" under the gate. Correct the gates such that no gaps are greater than 4" through the gate, no gaps greater than 2" exist under the gate, and the gates are fully self-closing and self-latching. The latches on the gates must either by 54" from the bottom of the gate, or must require the use of a key card, fob, combination, etc. to open. Also, the horizontal gate bars are less than 45" apart, so they must be on the inside of the gate. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Observed there to be no sings stating "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" and "ADULTS SHOULD NOT SWIM ALONE". These signs must use exact wording provided and all the letters of these two signs must be at least 1" high. These signs must be provided. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed emergency KINGS III box not to function properly. Box provided no sound or voice communications. Box must provide proper sound and communication, and must have a functional call-back phone number for the box itself. Observed call box not to have pool address or box call-back number posted at the box. Pool closed to swimming until call box issues are resolved and the Health Department approves corrections. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. Repair flow meter. |