NameCORTLAND COTSWOLD
Address4817 WATER OAK RD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/18/2016
Final Score @ Grade
28
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed last log book entry to be from July 2016. Main drains, Cl2, pH, must be checked and recorded every day the pool is open to swimming. Total Alkalinity and Cyanuric Acid (if used) must be checked and recorded 1 time a week.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy badly damaged and to have rope removed. Rope must be 39ft. long when attached to buoy.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gaps >4" through and under gates. Observed fence cross members to be able to form foot holds. Fence build in 1986.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed Lawson Aquatics MLD-SG-1818 to be recalled. Recalled main drains cannot be used.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter stuck.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at backflow.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed hand sink to reach 114F. No more that 110F is allowed.