NameCORTLAND COTSWOLD
Address4817 WATER OAK RD
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/9/2015
Final Score @ Grade
26
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed chlorine residual to be at .7ppm. A residual of 1.0ppm or higher must be maintained. IS issued. Pool may not be open for swimming without proper disinfectant residual.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No •Observed EQ lines to be plugged inside the bottom of the skimmers. This is no longer allowed. Lines must operate properly with proper fittings.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed vacuum port to not have a plug. A plug was provided during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed the gates to have gaps that a sphere greater than 4" could pass through. The fence has a section where the cross pieces on the outside of the fence can act as a foothold for climbing. The pool was built before 2010.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed pump system to be non-functional. IS issued. Pool may not be open without properly functioning circulation system.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at backwash discharge. A proper air gap is required.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed hot water in bathrooms to be at least 120F. Hot water shall be no higher than 110F.