Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameASHTON SOUTH END
Address125 W TREMONT AVE
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/20/2026
Final Score @ Grade
20
General CommentsConducted inspection with CPO Stephen Gray. All immediate suspension items were corrected during the inspection. Pool heated but heater not currently operating. Filtration pump meter: 70 gpm. This is not a suction hazard. The filter can be damaged. Recommend lowering to keep system operating properly. Feature Flow meter: 110gpm Permit Restriction: 1) Filtration Pump - Flow meter must remain operable. Flow required at 52 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Feature A - Flow meter must remain operable not to exceed 119 gpm due to drain cover flow restriction. Suction Hazard. Fire pump tied to drains. Pump located on lower level. Patterson FP[1]C0178833-01350 hp pump. Const. Date: 5/27/2009 Rope Length: 27' Night Swim?: No

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. 8.1 pH was recorded. Adjusted to 7.2pH. Corrected during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537b Pool walls shall be maintained in good repair. Tiles are missing in an area near steps. Shown to CPO during inspection. No permit action.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Grout missing around skimmers and coping in areas. Shown to CPO during inspection. No permit action.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Pool phone number posted was incorrect. CPO added correct phone number during inspection. Corrected and no permit action.