Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameASHTON SOUTH END
Address125 W TREMONT AVE
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/30/2026
Final Score @ Grade
6
General CommentsConducted inspection with CPO and property manager. Pool placed on A status and remains in good standing. Property installed new AcuFlow flow meters. Submit updated PDSC for approval of new flow meters prior to May 31st 2026. Pool heated but heater not currently operating. Feature Flow meter: 100gpm Permit Restriction: 1) Filtration Pump - Flow meter must remain operable. Flow required at 52 gpm to 63 gpm to meet turnover and flow restriction of the filter. 2) Feature A - Flow meter must remain operable not to exceed 119 gpm due to drain cover flow restriction. Suction Hazard. Fire pump tied to drains. Pump located on lower level. Patterson FP[1]C0178833-01350 hp pump. Const. Date: 5/27/2009 Rope Length: 27' Night Swim?: No

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Dialing instructions missing. CPO added dialing instructions. Corrected and no permit action.