Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameASHTON SOUTH END
Address125 W TREMONT AVE
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/24/2022
Final Score @ Grade
32
General CommentsInspection completed with Stephen Gray present. Permit immediately suspended due to the following: 1. Chlorine at 0.0ppm. 2. The pH at 6.8. 3. Water with low visibility. Correct the above items and contact Eli Freese at 704.621.2298 to reopen the pool. The following items will cause an intent to suspend to be issued if not corrected when pool is reopened: 1. Illegible flow meter, cannot read numbers as they have worn off. 2. Landscaping obstructing safety signs.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No .2535(2) Main drains must be clearly visible from the pool deck. Observed zero visibility of main drains due to large quantities of sodium bicarbonate being added to increase pH. Immediate suspension issued.
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0.0 ppm. Permit suspended.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Permit suspended.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool deck near emergency phone. CDI- rearranged.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Observed signage obstructed by landscaping.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed numbers worn off of flow meter, could not obtain accurate reading for this reason. Replace flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed leak in flow meter causing water to pool on pump room floor.