| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No place for main drain checks on sheet, no checks for this month. Cyanuric acid checked monthly currently. Check daily Cl, pH, main drains and temperature when heater is on. Check at least weekly TA and CYA. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Vacuum plug missing. Port shall be plugged when not in use. - Corrected by operator.
Bubbler pumps actually Pentair Whisperflo WFE-8, 2 HP pumps. Submit updated PDSC forms. - Immediate suspension item.
Main drains for bubblers not VGB approved for wall installation with no sump. Provide VGB approved covers and submit updated PDSC form. - Immediate suspension item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Pool with 43 foot wide steps and only one handrail. Handrails should be placed no more than 10 feet apart. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs too close to pool edge. Provide at least 6 feet clear walkway around pool. - Corrected.
Some pavers wobble, have > 1/2" offset, or are broken. Maintain pavers secure, in good condition and with less than 1/2" offsets. Operator has pavers on order. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
New liquid chemical feeder installed, no room in chemical storage room. Recommend storing away from equipment.
Very low flow for ventilation, grates mostly blocked. Clean fan and grates to allow for proper ventilation. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Mirror in men's restroom cracked at faucet. Recommend replacing with shatterproof mirror. |
|