5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Record page made of copies with main drain checks already checked daily.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator printing new record page to add daily main drain checks. Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder at end of pool loose, missing rubber stoppers.
.2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope broken and retied, not in good repair at time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced and cut to 23’. Corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lighting by main drains out at time of inspection. .2524(d) Provide sufficient underwater lighting.
*30 Day ITS item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Callback number starting to fade on signage.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator reposted number and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items within 3’ of piping and equipment in pump room. Hose bib in restroom with no antisiphon device. Vent fan in chemical room heavily rusted, not working at time of inspection. Light in chemical room out. Pool built '09. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
.2534(6) Provide sufficient lighting in chemical storage room. |