Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSPRINGHILL SUITES
Address12325 JOHNSTON RD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/16/2024
Final Score @ Grade
16
General CommentsMotor appears new, THP 1.65, advised ensuring electrical permits were pulled and referring to Code Enforcement. Note: Door to outside starting to rust in latch. Rope started to fray for buoy. Advised repairing before severity worsens. Copies of record sheets have main drain checks already checked. Use new sheet (download from charmeck pools) and ensure drains are being checked daily.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers observed with debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
22 6 Premises: emergency telephone provided No No No Static heavy in phone line, unable to clearly hear both ways. .2530(f) Emergency phone shall remain operable. Operator replaced phone and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3’ of piping and equipment in pump room. Hose bib in restroom with no antisiphon device. Vent fan in chemical room heavily rusted, not working at time of inspection. Light in chemical room out. Pool built '09. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(6) Provide sufficient lighting in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 2009. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water damage/peeling drywall surface beside toilet in restroom. No paper towels in restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. Provide hand drying. Operator replaced paper towels and corrected.