General CommentsContact Marie Daley at 704-507-6806 when items are corrected. 10/4 for emergency phone. Ladder and flow meter 30 day ITS items. Motor has been replaced, ensure electrical permit(s) pulled.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder at end of pool loose, missing rubber stoppers, missing slip resistant tread and missing a step. .2521 Install ladders per manufacturer instructions. .2521(b) Ladders shall have slip-resistant tread.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and tables within 5' of pool. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved and corrected.
22 6 Premises: emergency telephone provided No No No Static heavy in phone line, operator unable to clearly hear both ways, but does dial out in case of emergency. Allowing 7 days, 10/4 to correct. Failure to repair phone will result in immediate suspension of permit. .2530(f) Emergency phone shall remain operable.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of visit. .2518(g) Keep flow meter operational. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3’ of piping and equipment in pump room. Hose bib in restroom with no antisiphon device. Pool built '09. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 2009. .2513(b) Filter backwash shall be discharged through an air gap.