| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing one of two weirs at time of inspection. .2518(k) Replace missing weirs.
*permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder at end of pool loose, missing bottom step.
.2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection.
.2530(a) Lifesaving equipment should be conveniently located. Keep accessible. Operator untangled and corrected.
Body hook pole observed with telescoping pole at time of inspection.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible.
.2530(a) Provide at least 12 ft. long pole with body hook securely attached. Operator replaced part of pole and added pins to secure and make non-telescoping. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and tables within 5' of pool.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved chairs/tables and corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational at time of visit. .2518(g) Keep flow meter operational.
*permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Muratic acid stored over dry chemicals in chemical storage. Liquid should be stored under dry chemicals. Operator moved and corrected.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built 2009. .2513(b) Filter backwash shall be discharged through an air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Backflow preventer broken on at hose bib in restroom. Provide backflow prevention device on all hose bibs. |
|