Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHALTON PARK APARTMENTS
Address17701 HALTON PARK DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/5/2026
Final Score @ Grade
28
General CommentsOBSERVED PDSC FORM TO BE INACCURATE AS TO THE EQUALIZER LINE COVERS. EQUALIZER LINES IN THE POOL ARE PLASTERED OVER AND PLUGGED IN THE SKIMMERS. THE PDSC FORM SAYS THE POOL HAS 5 OPERABLE SKIMMERS WITH AQUASTAR 6HPHA COVERS. A NEW ACCURATE PDSC FORM MUST BE SUBMITTED THE THE HEALTH DEPARTMENT MAIN OFFICE AND APPROVED BY 5/12/2026 OR THE POOL WILL BE CLOSED. THE MAIN DRAINS COVERS EXPIRE 5/16/2030 ENSURE THAT ANY WINDOWS THAT OPEN ONTO THE POOL DECK DON’T OPEN MORE THAN 4 INCHES. THE POOL IS NOT APPROVED FOR NIGHT SWIMMING. THE SIGNS ON THE POOL INDICATE THE POOL IS OPEN UNTIL 10PM. THE SIGNS MUST BE CHANGED TO REFLECT THAT THE POOL CANNOT BE OPEN FOR SWIMMING AFTER DUSK OR BEFORE DAWN. POOL HAS A DEADLINE TO CORRECT THE DEPTH MARKER, THE FLOW METER, THE DOORS ONTO THE POOL DECK, AND THE VACUUM LINE CAP. DEADLINE IS 6/4/2026. POOL ALSO WILL NOT BE ISSUED A NEW PERMIT ON JUNE 1ST 2026 IF CORRECTIONS ARE NOT MADE BEFORE THEN. POOL WILL BE CLOSED DUE TO THE NEW PERMIT NOT BEING ISSUED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 6.8 upon arrival. It was corrected to 7.5 -CDI
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 1 weir missing out of 5 total. Replace the missing weir. No permit action taken.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed missing depth marker on the deck next to the stairs at one of the 3 foot ends of the pool making the distance between them 29 feet. Provide a correct marker at the correct distance.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence is not built to current specifications. The are less that 45 inches between horizontal fence pieces. No permit action taken. Pool was built prior to 2010. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed men’s bathroom door not self-closing and party room door not self-latching or audibly alarmed. Correct these doors.
22 6 Premises: emergency telephone provided No No No Incorrect phone number posted at emergency phone. Corrected onsite. -CDI .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Correct phone number was determined to be 704-937-1367.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter to be stuck. Correct the flow meter. Pool does not have a flow restriction. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Observed vacuum line cover to have a lid that is no longer latching. Pool was built prior to 2010 and can have either a cap with a latching lid, or a solid screw in plug as long as neither protrude more that 2” into the pool from the wall. Either provide a cap with a latching lid or a solid screw in cap.