Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 6.8 upon arrival. It was corrected to 7.5 -CDI |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 1 weir missing out of 5 total. Replace the missing weir. No permit action taken. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
Observed missing depth marker on the deck next to the stairs at one of the 3 foot ends of the pool making the distance between them 29 feet. Provide a correct marker at the correct distance. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence is not built to current specifications. The are less that 45 inches between horizontal fence pieces. No permit action taken. Pool was built prior to 2010.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Observed men’s bathroom door not self-closing and party room door not self-latching or audibly alarmed. Correct these doors. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect phone number posted at emergency phone. Corrected onsite. -CDI
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Correct phone number was determined to be 704-937-1367. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed flow meter to be stuck. Correct the flow meter. Pool does not have a flow restriction.
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010.
Observed vacuum line cover to have a lid that is no longer latching. Pool was built prior to 2010 and can have either a cap with a latching lid, or a solid screw in plug as long as neither protrude more that 2” into the pool from the wall. Either provide a cap with a latching lid or a solid screw in cap. |