Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHALTON PARK APARTMENTS
Address17701 HALTON PARK DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/8/2024
Final Score @ Grade
20
General CommentsInspection led by Emily Hartis under supervision of J. Bjorneboe. Observed small chip in deck on right side. Repair.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed a pH of 8.2 at time of inspection. Immediate suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed intermittent daily records and missing total alkalinity and acid records.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Ladders shall have slip-resistant tread. Observed ladder closest to fence missing slip resistant tread on 2 of the stairs. .2521 Install ladders per manufacturer instructions. Observed ladder closest to entry doors without end caps.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one inlet cover missing. Replace.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Unable to determine if gates are self closing, self latching due to bike locks. Ensure gates are unlocked when pool is open. .2537(b) All gates and doors shall be self-closing, self-latching.