3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 6.8 at time of inspection. Raised to 7.2 during inspection. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Alkalinity checks not recorded weekly. Record weekly. Intent to Suspend issued. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Some build-up starting on wall depth markers. Keep clean and clearly visible. Continue to monitor and clean as needed or if not visible. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder missing end cap and >6" from pool wall to ladder rung. Replace end cap and maintain 3" to 6" between wall and ladder rung.
One ladder with missing 3rd ladder rung. Replace prior to 2021 operating season. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One wall return missing fitting. Replace fitting. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
<45" between horizontals on barrier. Plexiglass on gates into pool. Pool built pre-2010. Maintain 45" between horizontals.
Door from bathroom not self-closing, self-latching. Could not verify door from fitness room to self-close, self-latch. All doors on to pool deck shall be self-closing, self-latching. Intent to Suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck, not operational. Maintain operational flow meter. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Storage in chemical storage room. Chemical barrels stored in pump room. Maintain storage so that chemical storage room can be used for storage. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >120 F. Maintain at 110 F or below.
Toilet seat loose in women's restroom. Keep fixtures in good repair. |