| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Spotty record keeping. Rarely check Total Alkalinity and Cyanuric Acid. Main drain cover damaged. Check daily Cl, pH, main drains and record daily pool maintenance activities. Check at least daily Total Alkalinity and Cyanuric Acid. Maintain Cyanuric Acid at no more than 100 ppm. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Main drain cover damaged. Provide A112 approved main drains secure and in good condition. - Immediate suspension item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers with debris. Clean regularly. One skimmer return mostly clogged with leaves. Provide functional skimmers.
Some skimmers missing weirs. Provide functional weirs. - Intent to suspend item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth marker on pool wall faded. Provide depth markers on 6x6 tile no more than 25 feet apart. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders loose, missing endcaps, missing steps, and extending more than 6 inches into the pool. Provide ladders in good condition and extending 3-6 inches into the pool. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Fiberglass pole for body hook cracked. Provide body hook securely attached to 12 foot non-collapsible pole. - Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Section of fence behind bushes missing two pickets so that people can sneak into the pool. Provide fencing with no gaps > 4". - Intent to suspend item.
Both gates not self-closing and self-latching. Make gate self-closing and self-latching.
Windows from the clubhouse capable of opening more than 4 inches. Install window limiters or alarms so that windows cannot open more than 4 inches or alarmed to notify office staff that window is open. - Intent to suspend issue. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Gaps greater than 1/2 inch between sections of deck drains. Provide decking with no gaps or offsets > 1/2 inch. - Intent to suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Pool not permitted for night swimming. Posted pool hours show that pool closes after dark. Change hours to reflect that pool is not permitted for night swimming. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pressure guages for both pool filters not functioning. Provide working pressure guages for the filters. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Dry chemicals stored on the floor in the pump room. Store off the floor or in a bucket.
Liquid chlorine and liquid acid drums stored in the pump room. Store all chemicals in the chemical storage room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Provide soap in men's restroom.